Replacement of a Failed Embankment Designed to Accommodate Large Settlement: A Case Study
Thick deposits of soft, normally to slightly preconsolidated, organic clay are common at low elevations along the riverbanks of southeast Texas. Both the moisture content and liquid limit...

Settlement Analysis of Landfill Liners over Deep Mined Areas
Tensile strains due to differential settlement from past mining activities were evaluated for a landfill liner. The landfill cell encompasses 20 acres and is located on a subsurface profile...

Settlement Predictions at a Florida Port Facility
A paved container storage area approximately four acres in size has been constructed at the existing Port of Fernandina in Fernandina Beach, Florida. Approximately one-half of the site...

Nonlinear Undrained Lateral Response of Rigid Drilled Shafts Using Continuum Theory
The nonlinear undrained response of rigid drilled shafts under static lateral and moment loading is evaluated within the context of elastic continuum theory. The approximate approach utilizes...

The Role of Shale Pores in Settlement
Waste fills resulting from the mining of coal in Appalachia should ideally consist of large, free-draining sedimentary rock fragments. The successful performance of these embankments is...

A Study of Alkalinity Leaching and Residual Strength of Alkaline Stabilized Sludge
The addition of sufficient amounts of quicklime or other alkaline earth oxides to dewatered sludge raises both the pH and temperature of the sludge, resulting in microbial inactivation....

Practical Method for Scour Prediction at Bridge Piers
A practical method is presented for prediction of local scour at bridge piers which is based on a comparison of many well known equations and supported by field data. This equation includes...

Comparison of Headcut Advance Testing and Soil Test Results
This paper presents the results of a study conducted in a flume to determine headcut advance rates of two base soils compacted at various compaction moistures and placement energies. The...

Width Adjustment: Relative Dominance in Unstable Alluvial Streams
The mechanisms that control the relative dominance of width adjustment in unstable streams are described. Specifically, the role of the following factors affecting the fluvial environment...

Spatial, Lattice and Tension Structures
This proceedings, Spatial, Lattice and Tension Structures, contains over 100 papers presented at the IASS-ASCE International Symposium 1994,...

Stiffness of Low Rise Reinforced Concrete Shear Walls
This report, Stiffness of Low Rise Reinforced Concrete Shear Walls, was prepared by the Working Group on the Stiffness of Concrete Shear Wall...

Improving Development Characteristics of Reinforcing Bars
Prepared by the Civil Engineering Research Foundation. Sponsored by CERF, This report describes the development and implications of a new concrete...

Building Code Requirements for Masonry Structures (ACI 530-92/ ASCE 5-92/TMS 402-92); Specifications for Masonry Structures (ACI 530.1-92/ ASCE 6-92/TMS 602-92); Commentary on Building Code Requirements for Masonry Structures (ACI 530-92/ ASCE 5-92/TMS 402-92); Commentary on Specifications for Masonry Structures (ACI 530.1-92/ ASCE 6-92/TMS 602-92)
Copublished with American Concrete Institute (ACI) and The Masonry Society (TMS) Building Code Requirements for Masonry Structures,...

Wet Mix Shotcrete Used in Subsea Tunnel Environments
To reject the claim that the use of accelerator in shotcrete reduces the compressive strength with time, lately cored samples were taken from an 18 to 19 years old concrete. A wet mixed...

The Influence of Water Glass on the Technological Parameters of Shotcrete
Shotcrete used in tunneling must follow a clearly defined early strength development in order to comply with stresses from rock deformations and drilling and blasting. Accelerators are...

Shotcrete Tests at the Fish Ecca Tunnel
The Fish-Ecca Tunnel is situated in the Eastern Cape and forms part of the Lower Fish Irrigation Scheme. About 25% of the 5032 m tunnel had to be lined with shotcrete. Between February...

An Identity Chart for Steel Fibers
Improvements in ductility and toughness by adding steel fibers to the shotcrete mix are sufficient to enable steel fibers to be used as replacement for steel mesh reinforcements. Steel...

Steel Fiber Reinforced Shotcrete?For Rock Support and Fire Protection
Rapid development in concrete technology and development of equipment has led to a change from dry hand-operated to wet robot shotcreting in Norway. Shotcrete of more than 100 MPa cube...

ASTM C666 (A) Freeze-Thaw Durability of Air-Entrained Wet- and Dry-Mix Shotcrete
In order to assess the freeze-thaw durability of shotcrete, six samples of dry-mix shotcrete and one sample of wet-mix shotcrete were mixed outdoors at Hydro-Quebec's research institute...

CenterCore Strengthening System for Seismic Hazard Reduction of Unreinforced Masonry Bearing Wall Buildings
The CenterCore technique of reinforcing unreinforced masonry walls was developed with the help of a National Science Foundation grant in 1984. The CenterCore strengthening system consists...

 

 

 

 